0333 004 4433
  • Sales

    CHILLERS

    Process Chillers

    OEM Chillers

    Free Cooling Chillers

    Low GWP Chillers

    AMBIENT COOLING

    Cooling Towers

    Dry Air Coolers

    Free Coolers

    Adiabatic Coolers

    TEMPERATURE CONTROL UNITS

    Temperature Control Units

    DESIGN & INSTALLATION

    Our Design & Installation Services

    DATA CENTRE COOLING SOLUTIONS

    CDU with Leak Prevention

    CRAC / CRAH Units

    ANCILLARIES

    Water Treatment

    Industrial Chilelrs
  • Hire

    CHILLERS

    Heat Pump Chiller Hire

    HVAC Chiller Hire

    Industrial Heat Exchanger Hire

    Low Temperature Chiller Hire

    Non Ferrous Chiller Hire

    Process Chiller Hire

    Water Cooled Chiller Hire

    Water Storage Tank Hire

    AIR CON

    Air Conditioner Hire

    Air Handling Unit Hire

    BOILERS

    Boiler Hire

    Electric Boiler Hire

    Fuel Tank Hire

    HEATERS

    Electric Heater Hire

    Heater Hire

    Industrial Heater Hire

    Office Heater Hire

    COLD STORES

    Chilled Storage Hire

    Low Temperature Fan Coil Hire

    FREE COOLING

    Adiabatic Cooler Hire

    ANCILLARIES HIRE

    Water Treatment
    Industrial Chillers Hire
  • Service
    • Emergency Breakdown
    • Glycol
    • Service & Maintenance
      • Air Conditioning
      • Chiller Maintenance
    • Spare Parts
    • Water Treatment
  • Industries
    • Agriculture & Farming
    • Automotive & Manufacturing
    • Brewery & Distillery
    • Petrochemical, Oil & Gas
    • Data Centre Cooling
    • Defence, Military & Government
    • Education & Research
    • Facilities Management
    • Food & Beverage Manufacturing
    • Metal Finishing & Tooling
    • Pharmaceutical & Medical
    • Plastics, Rubber & Packaging
  • News & Success Stories
    • Success Stories
    • Latest News
  • About
    • Careers
    • FAQs
  • Contact
  • Sales
    • Chillers
    • Ambient Cooling
    • Temperature Control Units
    • Design & Installation
    • Data Centre Cooling
    • Ancillaries
  • Hire
    • Chiller Hire
    • Air Con Hire
    • Boiler Hire
    • Heater Hire
    • Cold Store Hire
    • Free Cooling Hire
    • Ancillaries Hire
  • Service
    • Emergency Breakdown
    • Glycol
    • Service & Maintenance
      • Air Conditioning
      • Chiller Maintenance
    • Spare Parts
    • Water Treatment
  • Industries
    • Agriculture & Farming
    • Automotive & Manufacturing
    • Brewery & Distillery
    • Petrochemical, Oil & Gas
    • Data Centre Cooling
    • Defence, Military & Government
    • Education & Research
    • Facilities Management
    • Food & Beverage Manufacturing
    • Metal Finishing & Tooling
    • Pharmaceutical & Medical
    • Plastics, Rubber & Packaging
  • News & Success Stories
    • Success Stories
    • Latest News
  • About Us
    • About Us
    • Careers
    • FAQs
  • Contact

0333 004 4433

  • News

Giving Energy Savings an Extra Boost

  • September 16, 2016
When Aqua Group recently installed a 3mW cooling system with pumps controls based on Danfoss drives, the overall energy efficiency was already very satisfactory. However, as part of the installation, Aqua asked an engineer from Greenville Electrical to visit the site to see if there was any way efficiency could be improved even further. The engineer examined the system and, by making a small change to the drive configuration, further boosted the efficiency of the cooling system.

Aqua Group, the UK’s leading specialist in process cooling and associated products and services, designed, manufactured and supplied the 3mW cooling system for a major manufacturer of food packaging products. The system includes two sets of pumps, one with two 45 kW pumps, the other with two 55 kW pumps. All of the pumps are controlled by Danfoss VLT® FC102 HVAC drives.

As originally configured, each of the pumps in a pair operated independently with closed-loop speed control and its own individual pressure transmitter. This arrangement was chosen so that if one of the pumps failed, the other could continue to operate and maintain the pressure in the system.

While this arrangement is perfectly satisfactory from an operational standpoint, it means that most of the time the pumps will be running at different speeds to maintain the required pressure.

An alternative is to operate the pumps in master-follower mode, where the drives for the two pumps are interconnected with one designated as the master and the other as the follower. With this mode of operation, the follower drive tracks the speed of the master, which means that both pumps run at the same speed and the speed of both is controlled simultaneously to deliver the required pressure.

The drive configuration suggested by the Greenville and Aqua Cooling engineers was that the master drive should, in normal circumstances, operate in closed-loop mode with its speed controlled by the signal from the pressure transmitter. Under these conditions, the follower drive operates in open-loop mode and tracks the speed of the master drive. If the master drive fails or is turned off for any reason, the follower drive automatically reverts to closed-loop operation with its speed controlled by the signal from the pressure transmitter. The modification was subsequently agreed and the drives were adjusted to the new configuration – a simple and inexpensive task that was quickly accomplished.

The results were gratifying. Before the change, the pumps in the set with two 45 kW drives typically had pumps running at different speeds. The total load was around 58 kW. With the new configuration, both pumps typically operate at around 40 Hz, with a total load of around 45 kW. This is a saving of 13 kW, which equates to no less than 113,880 kWh per year, assuming that the pumps run continuously.

The results from pumps in the set with two 55 kW drives were equally impressive. Previously, these ran at different speeds, with a total load of 85 kW. After the change, they both now run at 42 Hz, with a total load of 65 kW. Here the saving is 20 kW, equivalent to 175,200 kWh per year.

In these days of high and ever-increasing energy costs, the savings are very significant, especially if taking into account the minimal time, effort and expenditure involved in re-configuring the drives to achieve them. As this story has amply demonstrated, fitting Danfoss drives is an excellent step toward energy efficiency; but seeking advice from Danfoss or an appointed Competence Centre about how to optimise that energy efficiency is also a wise move that can bring big benefits!

 

Latest Success Stories

Check out industry news, success stories and more.

Tactical Hire Completes The Solution

Read More »
Free Cooling solution

Free Cooling Solution Reduces Operating Costs by 50%+ for Packaging Manufacturer

Read More »
rubber

A Contingency Plan That Delivers

Read More »

Bespoke Design Solution Overcomes Space Challenge

Read More »

Unit 6 Brickfield Lane

Chandler’s Ford

Industrial Estate

Eastleigh Hampshire

SO53 4DP

Registration no. 13262716

VAT No. 382720395

Tel: 0333 004 4433

Email: sales@aquacooling.co.uk

Linkedin Twitter Facebook Youtube

Our Services

  • Chillers
  • Design
  • Boilers
  • Heaters
  • Servicing
  • Parts

Site Links

  • Home
  • Industries
  • News
  • About Us
  • Contact Us
  • Careers
© Copyright Aqua Cooling Ltd 2021. All Rights Reserved.

Terms & Conditions Hire  |  Terms & Conditions Sales & Service  |  Privacy Policy

This website uses cookies We use cookies to give you the best possible user experience, tailored service and functionality. Information from your visit to us may also be shared with our advertising and analysis partners. Click here to read our cookie policy. In order to customize advertising, these partners may in turn combine the information with other information you have provided when using their services.